Connector Insulation Material Selection

Material Type Temperature Range (℃) Dielectric Strength (kV/mm) Dielectric Constant (1GHz) Mechanical Strength (MPa)  Moisture Resistance  Cost  Application
PA66 -40~105 18~22 3.8~4.2 70~90  Average  Low Consumer electronics, industrialcontrol connector housing
PA66+30%GF -40~120 20~25 4.0~4.5 100~130 Average Medium Automotive & industrialequipment connector housing
PBT -40~100 15~20 3.2~3.6 50~70  Good Low Midlow end consumerelectronics connector housing
LCP -55~150+ 25~30 2.8~3.2 80~100  Excellent  High Highspeed, hightemperature, automotive connector housing
PA9T -40~120 20~25 3.6~4.0 90~110 Good  MediumHigh Balanced temperature resistance & cost, automotive & industrial equipment

Principles for Insulation Material Selection

1. Temperature Resistance Requirements

  • · Lowtemperature application (≤40℃): Adopt materials with good lowtemperature toughness (PA66, LCP) to prevent brittle fracture.
  • · Hightemperature application (≥125℃): Adopt hightemperature resistant materials (LCP, PA9T, PPS). For example, LCP for automotive enginebay connectors; PPS for aerospace connectors.

1. Electrical Performance Requirements

  • · Highspeed / RF connectors: Select materials with low dielectric constant and low dielectric loss (LCP, PPS) to minimize signal attenuation.
  • · Highvoltage connectors: Select materials with high dielectric strength (LCP, PA66+GF) to avoid electrical breakdown.

1. Environmental Conditions Requirements

1. Processing Technology Requirements

  • · Housings with complex structures: Select materials with good flowability (PA).

AMASS High current connector use the PBT which can help you  maintain stable connections in application scenarios such as high-intensity vibration, repeated high and low temperature impacts, small volume, and high current

 