Application of Silver in Connectors

Due to the poor durability of silver and unpredictable formation of oxide films, the design shall allow wiping or removal of oxide films at the contact interface during mating. Therefore, it is recommended that silver-plated contact interfaces be designed with relatively high normal force and adopt wiping structures wherever possible. Typical designs for silver-plated contacts generally adopt a normal force of 200 gf.

 

Given silver’s limited durability, it is recommended for low-cycle applications (e.g., 10 mating cycles). The actual number of durability cycles a specific connector can withstand depends on its design and application conditions. Surface treatments that reduce wear (such as lubricants) can increase the number of operating cycles where the silver plating performs reliably in a given application.

 

The use of a nickel underlayer is recommended wherever possible, with a minimum thickness of 1.25 μm. If alloying elements from the base copper alloy migrate to the silver surface, the properties of the oxide film will change significantly. This can occur via diffusion or mechanisms such as corrosion creep at breaks in the silver plating layer (similar to the behaviour observed with gold plating). Should these more tenacious films form at the contact interface, an increase in contact resistance (CR) is highly likely.

At elevated temperatures, oxygen diffuses rapidly through silver to the copper alloy interface. Blistering may occur if no nickel underlayer is applied. Furthermore, at temperatures above 150°C, the nickel underlayer prevents the formation of a weak silver-copper intermetallic layer, thereby avoiding adhesion issues.

The appropriate silver layer thickness depends on application factors, such as environmental severity, duration of temperature exposure, durability requirements, nickel underlayer configuration and surface treatment method. The silver plating thickness shall be determined based on these factors.

Typically, a thickness of 2 μm or above is suitable for most separable contact interface applications with a nickel underlayer. Where no nickel underlayer is applied, a thicker silver layer may be required to prevent corrosion products from the substrate reaching the surface. A thicker silver layer provides additional silver material between the atmosphere and substrate material, which may withstand more wear cycles before substrate exposure occurs.

ilver-plated contacts are generally not suitable for direct exposure to outdoor or industrial environments, as excessive reducing sulfides can cause severe tarnishing. Silver-plated contacts should also be kept away from environments containing high concentrations of hydrogen sulfide (e.g., paper mills), chlorides (such as salt spray), chlorine gas and/or ozone. If silver material must be used under such conditions, environmental sealing may be required to prevent excessive tarnishing.

AMASS High current connector use the silver which can help you  maintain stable connections in application scenarios such as high-intensity vibration, repeated high and low temperature impacts, small volume, and high current